ML Engineering · SERES · June–August 2026
Tactile sensing AI
& automated testing.
Magnetic tactile sensing
& machine learning
I led tactile ML and model development to improve how a robot finger estimates contact position and force. I also designed the test bed and built the software-side force control, automated tests, and analysis workflow. My work included reference-point selection, spatial-resolution methodology, test design, and calibration.
- Role
- ML Engineering
SERES · June–August 2026 - My contribution
- AI development, test-bed design, and automation
Characterization, calibration, and test methodology - Outcome
- Improved contact estimates
Programmable, repeatable experiments
My contributions
Test-bed design,
data collection & ML.
Experiment
Designing a force-controlled test bed
I designed a new test bed to replace a limited, inaccurate setup and make contact position and load repeatable. I developed the test methodology and test matrix to structure those experiments.
The Torbal setup was not force-aware. My software added force control, letting engineers specify target loads and run automated multi-step tests.
Measurement
Developing sensor characterization and calibration methods
I researched and developed methods for choosing the number of force reference points and contact locations, determining spatial resolution, and calibrating the system.
I also integrated automated data collection, graphing, and analysis into the testing software, connecting sensor readings with contact position and applied force for model training and evaluation.
Learning
Predicting contact position and force
I led tactile ML and model development, improving the previous model’s ability to estimate contact position and force from magnetic measurements.
The two-headed network uses a shared learned representation, then separates into position and force predictions.
Evaluation
Evaluating the model on held-out data
Evaluation used two training runs and a separate holdout run, with millions of measurements at each stage. MAE, RMSE, and model fit helped assess the predictions.
The improved model’s reported results include full-scale error below 1% and R² around 0.99 within the research setup.
Engineering outcome
Model accuracy
& repeatable testing.
The resulting platform connects controlled loading, sensor measurements, and model evaluation. I documented the software and methods so the experiments can be repeated and extended.
The previous system had reported MAE of up to 70% and RMSE of up to 100%, alongside a limited, inaccurate test bed.
- Reported full-scale error
- <1%Improved model · research setup
- Reported fit
- ≈0.99R² · research setup
Interactive learning lab
Explore contact and force prediction.
An educational simulation of contact, magnetic sensing, and learning, using synthetic data.